_waitForRconReadyOrExit resolved with an Error to signal the process
exited before RCON came up, which is an odd shape for a promise. It now
resolves when RCON is ready and rejects otherwise, with the error emitted
with the exit, or "RCON connection lost" when there was none.
Observable behaviour is unchanged. sendRcon rejects with the same
messages as before and stop ignores the rejection, as stopping is done
once the process is gone.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Waiting for exit alongside rcon-ready made sendRcon reject with the flat
"RCON connection lost" for every case, including the unexpected exits
that used to reject with the EnvironmentError saying why the server went
away, as events.once rejects on error events.
Have the paired wait capture the error emitted with the exit and hand it
back, so sendRcon throws that when there is one and falls through to the
old message when there is not, which is the kill path where no error is
emitted. stop() ignores the error as its job is done once the process is
gone.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
sendRcon waits for the rcon-ready event when RCON has not connected yet,
which is the same root cause as the stop() hang. events.once rejects on
error events, but _watchExit skips emitting error while the state is
stopping, and kill() sets that state before sending SIGKILL. exportData
does exactly that, so an RCON call racing the export never settles and
the request stays pending until the session closes.
Wait for exit as well, which leaves the existing RCON client check to
reject the call with "RCON connection lost" instead. Both call sites now
share a helper as the paired wait is identical.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
stop() waits for the rcon-ready event when RCON has not connected yet,
but nothing emits it once the process is gone, so the promise never
settles and the stop request stays pending until the session closes.
Wait for exit as well and drop the other listener when either fires.
Repro: send InstanceExportDataRequest to a stopped instance, then
InstanceStopRequest while the status is exporting_data. Instance.stop()
sees the server as running and calls server.stop(), then exportData
kills the process before RCON is up. The export finishes and the
instance reports stopped, but the stop request never gets a response.
Co-Authored-By: Claude Opus 5 (1M context) <noreply@anthropic.com>
Creates a scenario directory with the Clusterio modules patched into it
so the modules can be used outside of Clusterio. The command reuses the
save patching by zipping the scenario, running patch() on it and
extracting the result. Defaults to the freeplay scenario from the
Factorio install in the host config and all plugins enabled there.
Module loading in Instance.prepareSave is moved to patch.loadModules so
the command and the instance share it, and findVersion is exported from
server.ts so the command can find the freeplay scenario.
Zipped scenarios were tried as an output form but Factorio does not
pick them up from the scenarios folder, so only directories are written.
Co-Authored-By: Claude Fable 5.1 <noreply@anthropic.com>
An instance's factorio.version can now target a release channel such as
"stable" or "experimental" (any key from factorio.com/api/latest-releases)
in addition to "latest" and specific X.Y / X.Y.Z versions.
The controller proxies the latest-releases API through a ValueCache and
persists the last successful response to latest-releases.json, serving that
copy when the API is unreachable. On instance start the host resolves a
channel to the concrete version it points to and feeds it into the existing
checkForUpdates/findVersion path, so a channel auto-installs and runs like a
pinned version. The version selector in the web UI lists the available
channels alongside "latest".
Also clarifies the host log/error when a newer version cannot be downloaded
automatically because the host uses a direct (single-version) Factorio
install rather than a versioned directory.
Co-Authored-By: Claude Opus 4.8 (1M context) <noreply@anthropic.com>
These packages are obsoleted by the promises API to the built-in Node fs
module. The fs-extra package is also causing problems with broken APIs
that don't behave the same as Node's fs module, and throwing errors
without code properties on them.
The FactorioServer.checkForUpdates function would wrongfully assume that
the version running would always be listed on Wube's archive page, and
throw an error if this was not the case. Ignore version checking logic
if no suitable latest version could be found.
* Fix tests failing due to missmatched Factorio detection
When the configured factorio directory is full of junk then the tests
use the first directory it finds for one of its tests, while the server
code uses a more elaborate logic to figure this out.
Turns out this is complicating things more than needed. Simply trying
each entry in the directory and seeing if it works when treated as a
directory always work, regardsless of symlinks, junctions,
reparse-points or whatever else filesystem magic there is.
* Skip tests requiring Factorio if it's not present
Prevent confusing test failures by skipping all the tests that require a
working Factorio installation to sucteed, and print a warning at the end
of the test suite if tests may have been skipped due to this.
* Handle ENOTDIR when determining Factorio version
If the path to the factorio install contains a component that is not a
file then ENOTDIR may be returned on POSIX like systems. Treat this the
same as ENOENT so that detection logic works when used on a file.
---------
Co-authored-by: Hornwitser <code@hornwitser.no>
* Add ModDependency and version types
* Add warnings for mod dependencies
* Add warning for wrong factorio version
* Add fix issues button
* Add automatic dependency resolution and download
* Add abilty to check for updates
* Add extra test coverage
* One extra test
* Fix copy paste error
* Event types for controller
* Clean up ctl event emitters
* Event types for server
* Event types for lib
* Remove TypedEventEmitter
* Event types for webui
* Fix compile issues
* Small cleanup of connectors
By using sync file writes it prevents interrupts between the state change and the server process starting. Also adding error catching to reset the state following an error writing to the files.
Fixes: #676
Rewrite shutdown logic for Factorio servers to send a /quit command via
RCON for both Linux and Windows when stopping a server to avoid having
two confusingly intermixed code paths for Windows and Unix systems.
This makes shutdown on Windows tell clients the server shut down instead
of abruptly stoping to respond.
If during the startup of an instance the Factorio server is started up
to create a new save and the host shutdown in initiated then the
instance will be commanded to stop while the FactorioServer state is
"create". This was was not handled by Instance.stop leaving the
child_process running after the host is done shutting down.
Kill the FactorioServer on stop if the current state of it is stopping
or create to make sure the server actually stops.
Add suffixes like Ms and Ns to variables whos time unit is not in
seconds. This is aligning with a new code style of putting units
on variables that are not in SI base units.
Be consistent with the usage of tabs as indents in all JSON files in the
project. This makes it easier to configure editors to emit the right
indents when manually editing these files.
Remove extra whitespace, use more consistent spacing, add missing
semicolons, using dangling commas, break up long lines, consistent
multiline operator placement, add missing JSDoc strings and so on.